MB-SR50N EIGörsel
Partition Wall MB-SR50N EI

Fire Resistant Curtain Wall System

MB-SR50N EI fire-resistant curtain wall system has been developed for the creation of light and fire-resistant curtain walls as well as fire-resistant glass roofs in EI30 and EI60 fire resistance classes according to EN 1364-3 and EN 1364-1 standards. The system is classified as a structure that does not contribute to the spread of fire (NRO).

Air Tightness
Class AE 1050 Pa | PN-EN 12152
Water Tightness
Class RE1200 | PN-EN 12154
Heat insulation
>1.8 | W/(m2K)
Fire Resistance Classes
EI30 and EI60 | EN 13501-2
facadesExterior CompartmentsEI 30EI 60
CERTIFICATES
itb
GRY
GENERAL INFORMATION

Sistem Hakkında

MB-SR50N EI fire resistant curtain wall system, in EI30 and EI60 fire resistance classes according to EN 1364-3 and EN 1364-1 standards, in addition to light and fire resistant curtain walls, fire resistant glass It was developed for the purpose of creating roofs. The system is classified as non-contributing to the spread of fire (NRO) structure.

Profiles belonging to the basic MB-SR50N façade system are used in the system. The uprights have profile depths varying between 85–225 mm, and the horizontal posts have profile depths varying between 65–189.5 mm.

MB-SR50N system, facade interior creates a holistic façade grid layout by allowing the selection of post and registration profiles that will provide a smooth and aligned appearance on the surface. creates.

Design of fire resistant curtain wall system; joints with angles up to ±7.5’ in both directions, 90’ or 135° interior It allows the application of exterior corner joints and facades inclined from the vertical axis up to ±15°.

The system can also be integrated with MB-78EI fire-resistant doors, in which case the entire construction Maintains EI30 or EI60 fire resistance class

TECHNICAL DETAILS
Air Tightness
Class AE 1050 Pa | PN-EN 12152
Water Tightness
Class RE1200 | PN-EN 12154
Heat insulation
>1.8 | W/(m2K)
Fire Resistance Classes
EI30 and EI60 | EN 13501-2